This fictional example shows an electrician qualified since 2019, applying to a larger electrical contractor for an approved electrician role that carries testing, certification and qualified supervisor duties. Qualifications and card status are stated as dated facts, the competent person scheme position is described honestly as the business's registration rather than a personal badge, and every bullet shows volume, standard or outcome. Each decision is explained, three weak bullets are rewritten from the evidence behind them, and the editable download lets you replace every detail with your own. Nothing here describes a real person.

Illustrative example. An illustrative, invented electrician who completed a Level 3 electrotechnical apprenticeship in 2019, holds the 18th Edition and inspection and testing awards, and is the nominated qualified supervisor for a small domestic contractor. He is applying to a larger contractor for an approved electrician role. Every employer, date and figure is fictional.

The example document

Callum Oyelaran-Hughes

Electrician · Level 3 qualified · 18th Edition · Inspection and testing · ECS Gold Card

Stockport, Greater Manchester · 07700 900 318 · callum.oyelaran-hughes@example.com

Profile

Qualified electrician working in domestic and small commercial installation since completing a Level 3 apprenticeship in 2019. Carries out initial verification on every job and periodic inspection for landlords, issuing EICs, MEIWCs and EICRs to BS 7671. Nominated qualified supervisor on a three-person contractor's competent person scheme registration since 2024. Seeking an approved electrician role with testing and certification responsibility at a larger contractor.

Experience

Electrician and Nominated Qualified Supervisor — Fictional Peakside Electrical (domestic and small commercial contractor)

March 2021 – present · Three-person contractor working on rewires, new-build plots, landlord inspections and EV charge points across Greater Manchester.

  • Complete first- and second-fix installation on domestic rewires and new-build plots, typically two full rewires or four to five plots a month, to BS 7671 and the client's specification.
  • Carry out initial verification on every completed job and periodic inspection for landlords and letting agents, producing around 60 Electrical Installation Condition Reports a year with coded observations.
  • Act as the business's nominated qualified supervisor under its competent person scheme registration since 2024, checking the team's certificates and building control notifications before they are submitted.
  • Installed around 30 EV charge points since 2023, carrying out supply earthing checks and maximum demand assessment and issuing the certification and notification for each.
  • Follow safe isolation procedure on every circuit (prove, test, prove, then lock off and label) with GS38-compliant test equipment, with no reportable incidents since qualifying in 2019.

Apprentice Electrician, then Improver — Fictional Mersey Valley Electrical Services

September 2015 – March 2021 · Four-year Level 3 apprenticeship followed by two years as a qualified improver on commercial fit-outs.

  • Completed the Level 3 electrotechnical apprenticeship (installation) in 2019, including the AM2 practical assessment at the first attempt.
  • Installed containment, lighting and small power across around 40 small commercial units as part of a two-person team, working from the contractor's drawings and marking up as-installed changes.
  • Assisted with periodic inspection on commercial units and learned to complete the schedule of test results under supervision.

Education

  • Level 3 electrotechnical apprenticeship (installation), including the AM2 practical assessment, 2019
  • Level 3 award in the requirements for electrical installations (BS 7671, 18th Edition), 2023
  • Level 3 award in the inspection and testing of electrical installations (initial verification and periodic inspection), 2022
  • Award in the installation of electric vehicle charging equipment, 2023

Cards, registration and training

  • ECS Gold Card (Installation Electrician), current
  • Nominated qualified supervisor on the employer's competent person scheme registration, 2024
  • Asbestos awareness and working at height refreshers, 2025
  • Full UK driving licence

Skills

Domestic and small commercial installation to BS 7671 (first fix, second fix, consumer unit changes) · Initial verification and periodic inspection; EIC, MEIWC and EICR completion · Fault finding on lighting, power and heating circuits · EV charge point installation, including earthing arrangement and load assessment · Safe isolation, GS38 test equipment, lock-off procedures · Competent person scheme notifications and qualified supervisor checks

Bullet rewrites, and the evidence behind them

Each rewrite was produced by asking an evidence question and using only the (fictional) answer. No number appears in a rewrite that is not in its evidence.

  1. Before

    Carried out electrical installation work on domestic and commercial properties.

    Evidence question

    What kind of installations, how many a month, and to what standard?

    Evidence (fictional)

    Domestic rewires and new-build plots; first and second fix; typically two full rewires or four to five plots a month; working to BS 7671 and the client's specification.

    After

    Complete first- and second-fix installation on domestic rewires and new-build plots, typically two full rewires or four to five plots a month, to BS 7671 and the client's specification.

  2. Before

    Responsible for testing and certificates.

    Evidence question

    Which tests, which certificates, how many, and at what stage of the job?

    Evidence (fictional)

    Initial verification on every completed job, with dead and live results recorded on the schedule of test results; Electrical Installation Certificates issued before handover; around 60 Electrical Installation Condition Reports a year for landlords and letting agents, each with coded observations.

    After

    Carry out initial verification on every completed job and periodic inspection for landlords and letting agents, producing around 60 Electrical Installation Condition Reports a year with coded observations.

  3. Before

    Good knowledge of health and safety.

    Evidence question

    What do you actually do on each job that shows it, and what is the record?

    Evidence (fictional)

    Safe isolation on every circuit: prove the tester, test the circuit dead, prove the tester again, then lock off and label; GS38-compliant test equipment; asbestos awareness and working at height refreshers in 2025; no reportable incidents since qualifying in 2019.

    After

    Follow safe isolation procedure on every circuit (prove, test, prove, then lock off and label) with GS38-compliant test equipment, with no reportable incidents since qualifying in 2019.

Try it on your own bullets with the bullet workbench, which asks the same questions and never adds a figure you did not supply.

Transferable skills in this example

  • Working to a written standard and recording the evidence

    Evidence: Every circuit tested and recorded on a schedule of test results; certificates issued to BS 7671 for each job.

    Where it helps: Quality, compliance and inspection roles; building control support; facilities and maintenance management.

  • Fault finding under time pressure

    Evidence: Diagnoses lighting, power and heating circuit faults on call-outs, isolating safely before working.

    Where it helps: Maintenance and facilities roles, building services, control and automation technician posts.

  • Explaining technical findings to people without the training

    Evidence: Explains coded EICR observations and remedial priorities to landlords, letting agents and tenants.

    Where it helps: Estimating, technical sales support, surveying and customer-facing technical roles.

  • Checking other people's work before it is signed off

    Evidence: Reviews the team's certificates and notifications as nominated qualified supervisor.

    Where it helps: Supervisory and quality assurance roles, site management, auditing and training positions.

Occupation notes

Hard requirements

  • A recognised Level 3 electrotechnical qualification (apprenticeship or NVQ route), the current wiring regulations award and, for testing roles, the inspection and testing award are what employers screen for first; give the titles and years rather than writing 'fully qualified'.
  • In England and Wales, registration with a government-authorised competent person scheme lets an installer self-certify that notifiable domestic electrical work complies with the Building Regulations, instead of making a building control application for each job. Registration belongs to the business, so describe your part in it (for example nominated qualified supervisor) rather than calling yourself 'Part P registered'.
  • Principal contractors commonly ask for a current ECS card for site access; give the card type and expiry year in the extras, never the card number.

Vocabulary that belongs on the page

  • First fix and second fix, containment, consumer unit change
  • Initial verification: dead tests (continuity, insulation resistance, polarity) and live tests (earth fault loop impedance, prospective fault current, RCD operation)
  • Electrical Installation Certificate (EIC), Minor Electrical Installation Works Certificate (MEIWC), Electrical Installation Condition Report (EICR) with C1, C2, C3 and FI codes
  • BS 7671 (IET Wiring Regulations), 18th Edition and its amendments
  • Competent person scheme, notifiable work, self-certification, nominated qualified supervisor
  • Safe isolation: approved voltage indicator, proving unit, lock-off kit (HSE guidance note GS38 covers test equipment)
  • RCBO, SPD (surge protective device), AFDD (arc fault detection device), SWA (steel wire armoured) cable
  • ECS Gold Card (the electrotechnical industry card for qualified electricians)

Pitfalls specific to this occupation

  • Writing 'Part P qualified' or 'Part P registered' as a personal qualification: Part P is a part of the Building Regulations, registration is held by the business, and assessors notice.
  • Listing 'testing and inspection' as a skill without saying whether you hold the inspection and testing award, which tests you carry out, or which certificates you issue.
  • Leaving out qualification years and card expiry, so a recruiter has to ring to find out whether an electrician's 18th Edition award covers the current amendment.
  • Padding the resume with appliance repairs or general handyman work that an electrical contractor cannot count toward the role.

UK and US differences

  • UK: The competent person scheme route described here applies in England and Wales; Scotland and Northern Ireland run their own building control systems, so describe domestic certification in the terms used where you work.
  • UK: Agency and contractor adverts usually ask for the ECS card grade and the 18th Edition award first; put both in the headline.
  • US: US electricians are licensed at state or local level and work to the National Electrical Code rather than BS 7671, so a UK resume used in the US needs its qualifications explained rather than assumed.

Common questions

Should an electrician resume say 'Part P registered'?

No. Part P is part of the Building Regulations for dwellings, and competent person scheme registration is held by the business you work for or own. Say what is true: 'nominated qualified supervisor on the firm's competent person scheme registration', or 'all notifiable work certified through the firm's scheme membership'.

Do I need to list every test I can carry out?

Group them. 'Initial verification and periodic inspection to BS 7671, issuing EICs, MEIWCs and EICRs' tells an employer you hold the award and use it every week. A long list of individual tests reads like a syllabus rather than experience.